MODEL P50/A1600
ANIMAL CREMATORY SPECIFICATIONS
Ease of Use.
Auto ignition. No pilots to light. Set the timer and walk away.
Built-in skid facilitates placement
Fuel Efficiency
Rapid incineration means low fuel consumption.
Higher burn rate than smaller models.
Thick refractory lining in main chamber retains heat, increasing efficiency.
Quality Built to Last
Heat resistant aluminized steel.
Stainless steel stack.
The Benefits of Incineration . . .
SANITARY – Waste can be destroyed as fast as it accumulates.
Nothing is left to spread disease or to attract rodents and flies.
CONVENIENT – Fill the chamber and turn on the burner.
No watching required since timer automatically shuts down burner.
Alternative methods frequently require more time to manage and maintain.
THOROUGH – Leaves only sterile white ash and brittle bone fragments.
Reduces 1650 lbs of animal carcasses to approximately 77 lbs of sterile residue.
Applications
Thousands of incinerators are being used to dispose of animal carcasses and other pathological waste.
Due to the fact that this unit has a full length loading door, it is suitable for large carcasses like pigs, deer, goats, etc.
Features Overview
- Cost Effective
- Low running and maintenance costs.
- High pressure Fan Assisted Oil Burner
- Fully Automatic and simple to operate control panel
- Afterburner Preheat
- Variable time settings (can be set altered to meet requirements)
- Incineration Temperatures to 2372 degrees F
- 3/16” Steel Casing
- Fully insulated Dense Refractory Concrete Lining Rated to 2800 degrees F
- Solid Hearth to Allow Maximum Burnout
- Large Top Opening Lid For Easy Loading
- Wide Door For Ash Removal
- Stainless Steel or Lined Flue
- After Burner Fitted as standard
- 12 Month Workmanship Warranty.
- Optional Automatic Temperature Recording
|
Technical Specifications |
A1600 |
| Fuel | Gas or Oil |
| Cubic Capacity (cu ft) | 42 |
| Average Capacity | 1650 lbs |
| Minimum Avg. Fuel Consumed (units / hr) Depends on model, waste type & operation. | 1.4 Gal. Oil, 2.2 Gal. Lp, 200 cf of Ng |
| External Dimensions | |
| Length (in) | 122 |
| Width (in) | 73 |
| Height incl. flue (in) | 136 |
| Door Aperture (L x W in) | 30 x 79 |
| Door Load Height (in) | 42 |
| Internal Dimensions | |
| Length (in) | 83 |
| Width (in) | 30 |
| Height (in) | 32 |
| Operation | |
| Min. Operating Temperature | 1742 F |
| Max. Operating Temperature | 2400 F |
| Residency Time in Afterburner Chamber | Models Up to 2 Secs |
| Temperature Monitoring | YES |